Posts

The cost of solar power is at a record low.

A typical solar home can save hundreds or even thousands of dollars per year on their electricity bill.

As a volunteer with the Boston-based solar program Solarize Massachusetts and a solar homeowner, Carl Elkin, Engineering Lead for Project Sunroof, has always been surprised at how many people think that “my roof isn’t sunny enough for solar,” or “solar is just too expensive.” Certainly many of them are missing out on a chance to save money and be green.

Enter Project Sunroof, his recent 20% project. Project Sunroof is a new online tool that is being tested to help homeowners explore whether they should go solar. Available in the San Francisco Bay Area, Fresno (in central California), and the Boston area for now, the tool uses high-resolution aerial mapping (the same used by Google Earth) to help calculate a roof’s solar energy potential, without having to climb up any ladders.ProjectSunRoof2

If you’re in one of our test regions, simply enter your address and Project Sunroof will crunch the numbers. It first figures out how much sunlight hits your rooftop throughout the year, taking into account factors like roof orientation, shade from trees and nearby buildings, and local weather patterns. You can also enter your typical electric bill amount to customize the results. The tool then combines all this information to estimate the amount you could potentially save with solar panels, and it can help connect you with local solar providers.

Google has always been a big believer in zero-carbon energy, and solar power has been a central part of that vision — from accelerating the growth of rooftop solar, to helping finance the largest solar farm in Africa, to building one of America’s biggest campus solar arrays in Mountain View. While Project Sunroof is in a pilot phase for now, during the coming months Google will be exploring how to make the tool better and more widely available. If you find that your address isn’t covered by the tool yet, you can leave your email address and you will be notified when Project Sunroof is ready for your rooftop!

View a video on the introduction of “Project Sunroof” below.

 

Source: Google Green Blog

Demand response is an energy-saving tool that encourages customers to shift their electricity use to times of day when there is less demand on the power grid or when more renewable energy is abundant.

Karan Gupta at 77 West Wacker's Central Command Center

Karan Gupta at 77 West Wacker’s Central Command Center

This has been at the core of the work of Karan Gupta, a high-performance building consultant and Environmental Defense Fund Climate Corps fellow based in North Carolina. His host company, Jones Lang Lasalle, is the property manager for 77 West Wacker Drive, a 50-story office building in downtown Chicago. Here, his focus is on maximizing the benefits of demand response, which already have been implemented through multiple technologies.

Currently, 77 West Wacker is enrolled in the PJM demand response capacity market through a demand response service provider. There are standby payments for demand response commitments, meaning that the building is paid for simply making itself available to reduce energy demand when called upon to do so. In addition to these standby payments, the building is paid for with actual energy conservation as real demand falls below baseline demand during emergency events. The building also participates in voluntary price-based demand response, whereby energy conservation is performed in non-emergency events to take advantage of opportunities when real-time energy prices exceed the fixed rate that the building pays for energy.

Load-Shifting Makes It Easier To Bear

The software platform provided by the demand response service provider allows engineers to view the building’s baseline demand, real-time action alerts and forecasts for weather and energy prices. When the grid is stressed due to extreme weather or system lapses, the engineers receive notification, usually the day of, to enact demand response protocols. While extreme weather may or may not result in an emergency event, it almost always presents earnings opportunities through economic demand response.

For this reason, the team here is proactive and monitors weather forecasts throughout the Midwest and East Coast, and usually has taken action by the time emergency notification is received. In the summer, the primary form of action is “load shifting,” a process works by pre-cooling the building during early morning off-peak hours and reducing cooling demand during peak hours.

demandresponse

(Credit: Karan Gupta)

A hypothetical demand response event in which load shifting was used. In this snapshot, the red line represents the baseline and the green line represents actual building use. Actual use exceeded the baseline in the morning hours when building equipment ramped up to pre-cool the building (there is no penalty for going above the baseline during non-peak hours), and then around 10 a.m., the equipment ramped down for the rest of the day as it had to work less hard to maintain the lower temperature. During the period where the green line is below the red line, real-time energy prices are paid back to the building for the difference between baseline energy consumption and actual consumption.

BAS + VFD Spells Comfort’

When a non-weather event occurs, load shifting may not be an option, and instead a series of minor operational adjustments must be made to achieve the necessary reductions. Tenant comfort is an important consideration when making these adjustments, as reasonable temperatures and minimum levels of ventilation have to be maintained. Excessive ramping and cycling of equipment also should be avoided to prevent undue stress and shortened life. Where base building equipment adjustments alone are not sufficient, the building may send out notices for tenant involvement. Effective communication is critical for tenant satisfaction, but to that end, building management has performed exceedingly well, making efforts to educate occupants about the value of demand response.

The two primary technologies that have enabled demand response capability at 77 West Wacker are the building automation system and variable frequency drives. The BAS allows for monitoring and control of the various equipment from a central command center. This control is necessary to quickly enact demand response protocols while guarding the health, safety and comfort of the building occupants. In the past, motor-driven equipment such as fans and pumps either would run at full load or not at all, and when at full load, would be modulated by dampers or fans. A common analogy is using the brakes to control the speed of a car while pushing the accelerator to the limit. VFDs basically provide throttle control and allow for the modulation of such equipment.

Aiming Higher

The next step in fully implementing demand response at 77 West Wacker is enrolling into ancillary services, which are used to support the transmission of electric power from seller to purchaser (scheduling and dispatch, electric grid protection, etc.). While BAS and VFDs are a strong first step, further hardware and software investments will be necessary to make frequency regulation possible. To some extent, real-time control will have to be relinquished to the system operator, but the primary objective still will remain to maintain tenant satisfaction. Automated scripts that guide operational parameters within predefined limits occasionally will have to override signals to ramp loads up or down.

Cracking the code for successful implementation hopefully will release a new wave of revenue for property managers around the country while enhancing grid reliability.

 

Source: GreenBiz

On any given day, many of facilities management tasks are focused on conserving energy.

Whether it’s scrutinizing utility bills, making adjustments in the BAS, or championing for efficient retrofits, saving kilowatts never falls off the to-do list. But one that may been overlooked is one of the most important factors for energy performance – occupants.

The relationship facility managers have with tenants can be a wary one at best, fraught with skirmishes over space heaters, thermostat settings, and light levels. But with the growing impact of plug loads, building owners need to recognize that human behavior can make or break an efficiency program.

Consider how the vast majority of a building’s energy use is determined by occupant needs, from operating hours and lighting to heating and cooling. You might also have little to no control over the proliferation of computers, printers, desk lamps, and mobile devices that have become standard in any office or classroom setting.

“Plug loads can represent anywhere from 15 to 50% of a building’s energy use and are one of the fastest growing end uses of energy,” says Jaxon Love, sustainability program manager for Shorenstein Properties. “If you’re not looking at plug loads and developing a strategy to manage them, you’ve got a major blind spot in your overall energy efficiency program.”

Energy competitions unite occupants and facilities management as they work toward a common goal. Not only will plug loads become more manageable, but the nature of these challenges will engender a positive experience that can infect all aspects of your business model.

“Successfully engaging occupants as part of a performance team offers many advantages to the building owner,” says Alison Liaboe, director of communications and research for Ecova, an energy and sustainability management firm. “This includes reducing turnover, minimizing the cost of building operations, and increasing tenant referrals. A better performing building also benefits workers by improving their health and productivity.”

Nagging occupants to turn off equipment has never resulted in sustained energy savings – make them an extension of your FM team instead. By engaging tenants with fun and creative programs, property managers can turn passive employees into energy champions. The only loser is your utility bill.

To read about the energy conservation program developed by Shorenstein Properties that has resulted in up to 45% energy savings click here.

 

Source: Buildings.com